Export desk open · replies within one business day CE / FCC documentation on every shipment sales@rockhoodautomation.com

FGm series

FGm series — ten-axis pulse motion PLC

Ten pulse axes at 200 kHz with interpolation and electronic cam — a motion controller without leaving the pulse world.

10 pulse axes200 kHz32 DI / 32 DOCAD import

The FGm series is the pulse-type motion specialist. Ten pulse channels at up to 200 kHz, with real-time speed and position adjustment, drive ten servo drives simultaneously, with interpolation, CAD import and electronic cam. Counting covers 12 single-phase channels plus 6 AB-phase channels, and up to 8 expansion modules are shared with the FGs series.

The single model, FGm-64MT-AC, provides 32 inputs and 32 NPN transistor outputs in 216 × 92 × 80 mm and 769 g, from AC 100–240 V. Software is SamSoar II.

The distinction against PRO/MAX is worth stating: FGm generates pulses, PRO drives an EtherCAT bus. Ten pulse axes on FGm are cheaper than ten EtherCAT axes, and cheaper still when the drives on the machine are already pulsed. The moment the axis count passes ten, or the machine needs coordinated interpolation across more axes than pulse outputs can carry, the bus platform takes over.

Ten axes, no bus

Ten servo drives driven directly from pulse outputs, with real-time speed and position adjustment while running.

Counting to match

12 single-phase and 6 AB-phase channels for encoders and handwheels.

CAD to motion

Import a drawing and generate the path, with electronic cam for the synchronised stages.

Model
FGm-64MT-AC
I/O
32 DI / 32 DO (NPN)
Pulse axes
10 × 200 kHz
Counting
12 single-phase + 6 AB
Expansion
8 modules (shared with FGs)
Dimensions
216 × 92 × 80 mm
Supply
AC 100–240 V
Software
SamSoar II

Model range

FGm main unit

One model covers the family; the axis count is what distinguishes it.

ModelI/OOutputPulse axesExpansionSupplyW×H×D (mm)
FGm-64MT-AC32 DI / 32 DOTransistor NPN10 × 200 kHz8 modulesAC 100–240 V216 × 92 × 80

Weight 769 g. Interpolation, CAD import and electronic cam are built in.

Selection notes

How to choose within the range

  • Ten axes is the ceiling on pulses. Beyond that, move to PRO/MAX over EtherCAT.
  • DRIVE selection matters more than usual here: ten axes at 200 kHz need drives that accept 200 kHz pulse input, and the R8 P-variants do.
  • Share the FGs expansion modules — analogue and temperature channels come from the same catalogue.

Next step

Tell us what the machine has to do.