HVAC and refrigeration

An all-in-one body with eight PT100 inputs, and a 4G panel so the service team sees the alarm before the building manager does.

8 × PT100Remote alarmModbus to BMS4.3 / 7 in

The machine

Chillers, air handling units and heat pumps

An air handling unit is a temperature loop, a humidity loop, a damper, a fan and a valve, in a metal box on a roof. A chiller adds compressor staging and a condenser. Neither is fast, and neither is where a control engineer wants to spend a week.

What matters is the enclosure count and the service call. A rooftop unit with a panel, a controller and a separate temperature module is three boxes to wire, seal and label; an all-in-one body is one cut-out.

The control

What has to happen, and fast enough

The GT all-in-one pairs a 7-inch panel with 16 digital inputs, 16 transistor outputs and eight PT100/NI120 inputs in one body at DC 24 V. The control logic, the HMI and the sensor conditioning share one power supply and one enclosure.

For remote sites, an IoT HMI with a 4G module pushes alarms to the service team and allows a VNC session without a site visit. Modbus TCP on the panel's Ethernet port hands the unit's status to the building management system.

Recommended hardware

A typical bill of materials for this machine

These are the models the export desk quotes most often for this application — not the only valid combination.

FunctionRecommendedWhy
Operator panelGT-070-32MT-8PT7-inch panel + controller + 8 PT100 inputs in one body
Remote optionSK-070QS-GIoT panel with 4G module for unmanned sites
Valves and dampersS-E4AI2AOFour analogue inputs and two outputs, 16-bit
Compressor stagingBuilt-in relay or transistor outputsGT-070-30MR for relay loads

I/O counts and axis counts assume a mid-range machine. Send the actual list and the quotation will be sized against it.

Engineering notes

What usually goes wrong

  • For rooftop and plant-room units, the all-in-one removes a power supply and a serial cable from the BOM and from the commissioning checklist.
  • Push the alarm rather than waiting for a call: an IoT panel with a 4G module reports a high-pressure trip before the building manager notices the temperature.
  • Keep BMS traffic on Modbus TCP and the service traffic on the cloud module; mixing them on one link makes both harder to diagnose.
  • Specify PT100 rather than thermistor where the sensor cable runs more than a few metres.