Export desk open · replies within one business day CE / FCC documentation on every shipment sales@rockhoodautomation.com

EA series

EA series – the entry-level HMI

A real-time panel for builds where the HMI is a display, a serial port and a membrane keypad replacement — and nothing more.

3.5 / 4.3 / 7 inARM9 @ 300 MHz26K coloursSATOOL

The EA series is the entry level. It keeps a real-time operating system on an industrial ARM9 at up to 300 MHz, 128 MB of flash and 64 MB of DDR3, with a single COM port that integrates RS232, RS422 and RS485, USB download, 26K true colours and the usual configuration-protection mechanisms. FCC Class A and CE approval apply as they do across the range.

The naming rule mirrors the SK series: a size code (035, 043 or 070) followed by a cut-out letter, A or B. Where a build needs a small panel, a serial link and nothing else — a pump controller, a single-axis fixture, a stand-alone test bench — the EA does the job at a lower cost than an SK with interfaces the machine will never use.

Reach for an SK instead when the machine needs Ethernet, 4G, Wi-Fi, CAN, recipes, data logging or more than one serial port. The price difference between an EA and a base SK is small next to the cost of discovering that a port is missing after the panel is in the door.

Real-time, not Linux

A deterministic real-time system boots straight into the project; there is no desktop and nothing to close down.

One COM port, three standards

RS232, RS422 and RS485 share the single connector, selected in software — one cable family for any controller.

Same protection

Configuration encryption and password levels match the SK series, so a project cannot be lifted from the panel.

Screen sizes
3.5, 4.3 and 7 in
Colours
26K true colour
Processor
ARM9 up to 300 MHz
Memory
128 MB FLASH + 64 MB DDR3
Comms
RS232 / RS422 / RS485
Download
USB
Approval
FCC Class A · CE
Software
SATOOL

Model range

EA models by size

Resolution follows the diagonal. Cut-out letters (A or B) select the aperture — confirm the door drawing before ordering.

SeriesScreenResolutionProcessorMemoryInterfacesSoftware
EA-0353.5" (4:3)320 × 240ARM9, 300 MHz128 MB FLASH / 64 MB DDR3COM: RS232/422/485 · USB downloadSATOOL
EA-0434.3" (16:9)480 × 272ARM9, 300 MHz128 MB FLASH / 64 MB DDR3COM: RS232/422/485 · USB downloadSATOOL
EA-0707" (16:9)800 × 480ARM9, 300 MHz128 MB FLASH / 64 MB DDR3COM: RS232/422/485 · USB downloadSATOOL

The EA range is specified by size and cut-out; ask for the dimensional drawing for the exact aperture on an existing enclosure.

Selection notes

How to choose within the range

  • Choose EA for pumps, single fixtures, test benches and other machines that only need a serial link.
  • Move up to SK when the machine needs Ethernet, 4G, Wi-Fi, CAN, recipes, data logging or two serial ports.
  • SATOOL projects are separate from SKTOOL; the two editors do not share project files.

Next step

Tell us what the machine has to do.

Send the axis count, the I/O list or a photo of the existing panel. You get a model recommendation, a wiring note and a quote — usually within one business day.